There are also additional requirements where the door is the final exit point of a building.
Emergency exit door size requirements.
If there is a fire in the area where occupants are they are already being exposed to smoke fire and heat.
Stairways which are not used as an exit or emergency according to 1910 24 d may have a minimum stair width of 22 inches.
The osha exit route requirements 1910 36 g 2 state that the minimum width of any way of exit access shall in no case be less than 28 inches.
However most occupancies require additional width based upon the capacity of exit route requirements.
However guidance is provided in nfpa life safety code 101 section 7 10 8 3 1.
The maximum door leaf width is 48 inches to facilitate use in an emergency.
There should be no locks or catches.
The same requirements as above will apply to a fire exit door.
The minimum width permitted for a passageway used as an exit access is according to 1910 37 g 2 28 inches.
Many use a push bar system that will open the door when pressed down.
Doors must swing in the direction of exit travel.
The width of an exit route must be sufficient to accommodate the maximum permitted occupant load of each floor served by the exit route.
1910 36 d 3 an exit route door may be locked from the inside only in mental penal or correctional facilities and then only if supervisory personnel are continuously on duty and the employer has a plan to.
The nfpa emergency exit door requirements code states there is a maximum travel distance allowed to find an exit.
Door swing and arrangement a door in a means of egress should be side hinged or pivoted swinging.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
Inches provided that wheelchair use is not allowed in the room.
Objects that project into the exit must not reduce its width.
The door should open in the direction of evacuation.
Osha does not require the use of no exit.
The 22 inch stair width requirement applies to both interior and exterior fixed industrial stairs i e around machinery.
29 cfr 1910 36 g 3 objects that project into the exit route must not reduce the width of the exit route to less than the minimum width requirements for exit routes.
Outdoor exit routes are permitted but must meet the minimum height and width requirement for indoor exit routes and must.
Exit route doors must be free of any device or alarm that could restrict emergency use of the exit route if the device or alarm fails.
For existing structures the minimum width is 28 inches.